De-Esser

Model 9629

Kicks S.

Conventional De-Essing

Traditional de-essers use compression techniques. In addition to the threshold parameter used to set the processing level, there is a frequency controller for setting the center frequency of the process (with bandwidths generally up to 4 kHz). Processing therefore compresses the entire selected range, notjust the sibilant or S sounds. This results in the familiar and undesired side-effects such as lisping and a nasal-sounding vocal.

SPL's De-Essing

SPL’s Auto Dynamic De-Esser monitors the entire frequency spectrum and automatically detects the sibilant frequencies. The bandwidth is set so narrowly around the range of the sibilance that neighboring frequencies remain unaffected. This frequency band is mixed back into the main signal phase-inverted to cancel out the sibilance. The result is a sound-neutral, inconspicuous and extremely effective process. Even at high s-reduction values the de-essing has an egligible effect on the character and timbre of the voice.Auto-Threshold

Rounding our this outstanding concept is an automaticthreshold-adjusting function: Differences in the input levelcaused by the singer moving in relation to the microphone are automatically compensated, so that the selected reduction value remains constant. In traditional de-essers, the processing intensity drops off with increasing distance, and compressors placed after the de-esser for signal correction tend to respond incorrectly to the changed values.Male/Female

The SPL system doesn’t just look for sibilance in a wide ’general sibilance’ region of the spectrum. Instead, the user simply sets a front-panel switch to Male or Female to adjust for the vocal characteristics of male or female voices.Features

Balanced XLR and jack plugs for the in- and outputs, internal power supply with toroidal transformer, GND lift switch, relay hard bypass/power fail safety, voltage selector switch.

Specifications

  • Inputs and outputs:
  • Instrumentation amplifier, electronicallybalanced
  • (differential), transformerless
  • Nominal input level +6 dB
  • Input impedance =22 kOhm
  • Output impedance < 600 Ohm
  • Max. input level +24 dBu
  • Max. output level +22.4 dBu
  • Minimum load 600 Ohm
  • Relay hard bypass / power fail safety

Measurements

  • Frequency response 20 Hz-50 kHz
  • (50kHz= -3dB)
  • Common mode rejection > -80 dBu @1kHz
  • Total harmonic distortion 0.002% @ 1 kHz
  • Signal-to-noise ratio -93 dBu (CCIR 468-3)
  • Signal-to-noise ratio -98 dBu (A-weighted)

Power supply

  • Toroidal transformer 15 VA
  • Fuses (230/115 V) 315 mA/630 mA
  • GND lift switch, voltage selection switch 115 V / 230V

Dimensions

  • Standard EIA 19”/IHE 482 x 44 x 237mm
  • Weight 3.4 kg
  • Note: 0 dBu = 0.775 V